MASTER BV 400 indirect oil heater

Heating Power:
110 / 80 kW
375.000 / 237.000 Btu/h
94.600 / 68.800 Kcal/h

Fan:
plug fan
Total Air Pressure:
500 Pa
Max Air Temperature:
95 °C
Air displacement:
6.200 m³/h
Power fan motor:
750 / 1.400 W/rpm
Rated current:
6,8 A
Ductability:
50 m
Net weight:
230 kg
Flue tube:
150 mm
Protection:
IP 44
Fuel Consumption:
10,2 high mode / 7,7 low mode l/h
Flex tube:
2 tubes Ø 31 cm or 1 tube Ø 40 cm
Remote thermostat:
analog or digital
Product size:
2086 x 717 x 1233 mm
Tank capacity:
150 l
Summer ventilation:
yes
Power supply:
220-240/50 V/Hz
Box size:
1634 x 686 x 1468 mm


Model description

Clean hot air
Very low noise (72 dB)
Plug fan allows high air pressure 500 Pa
2 stage MASTER burner
Air feed kit
Rotomoulded tank
Socket for remote thermostat
High efficiency heat exchanger
Stainless steel combustion chamber
Trolley included
Forklift slots
Snorkel
Robust hook for crane hanging
Protection IP 44


Accessories

Room thermostat TH 5 with cable
3 m - 4150.109, 10 m - 4150.112
Digital thermostat THD with cable
5 m - 4150.106, 10 m - 4150.107
Nylon flex tube with bag, 7,6 m
1-way outlet
Ø 40 cm - 4515.361
2-way outlet
Ø 31 cm - 4515.360
Flex tube 1-way outlet
7,6 m - 4031.401
Flex tube 2-way outlet
7,6 m - 4515.553
(possible to connect to each other)
Quick connector to flex pipes for separate tank - 4035.232
Flex pipes to connect
external tank - ACC 281
2-way outlet
Ø 31 cm - 4034.480
Uplift kit - 4035.112
Air inlet kit - 4035.225

Air recycling, Use 2 tubes - 2 x Ø 30 cm
- 4035.068

Remember

Ventilation of the room
is neccessary to prevent
a deficiency in oxygen supply.


Useful links

Download catalogue
Watch video
Tips and tricks


MASTER BV 400 indirect heater


Powerful input plug fan

BV 400 has standard 1 output. diameter 40 cm
BV 400 can accept 2 outputs. diameter 31 cm (option 4034.480)

Optional robust hook

Control panel with thermostat socket (analog or digital)

The burner is protected
by a robust box

Allows 2 different heating powers:
80 kw and 110 kw

Optional separate air feed case kit allows to connect a flex tube for combustion air ducting. Very useful when used in polluted rooms

Fuel preheater is optional, fuel filter is outside

Robust, rotomoulded fuel tank and large pneumatic wheels

When required, in case of relevant change of altitude, it is very easy to adjust the combustion